About
Andramed
Andramed
It is probably a combination of many factors that has made us successful since 2004
the good collaboration of a medium-sized family company; the site in the heart of Germany’s medical technology region around the University of Tübingen; our “typical Swabian” meticulousness and our extremely high quality standards; the commitment to just a few, but therefore all the more high-quality niche products, and the collaboration with doctors to find ever-better solutions. All this has contributed to our first-class reputation and making us so well-known – as well as to our products being used worldwide.
Based on regular input from the market, we are constantly developing innovative products and technology in close cooperation with our valuable partners. The creative, dynamic process starts when our professional team takes one technical problem and combines the most modern technology with their excellent skills in order to find the perfect solution.

ANDRABALLOON
The new AndraBalloon represents the new generation of non-compliant PTA-Catheters optimized for dilation of large volume vessel and especially usefull as a delivery system for intervention with AndraStent.
- Non-compliant balloon made of PA for high pressure
- 100% tested at 7kpa (7bar)
- Optimized folding for better rewrapping and easy repassage
- Coaxial shaft design for fast inflation and deflation
- Optimized PTA-Balloon for Stent Delivery System
- 2 X-Ray marker on the innerschaft
- Atraumatic tip
- Catheter length: 120 cm
- Recommended sheath: 7F – 13F
- Diameter balloon: 10 mm – 32 mm
- Length balloon: 20 mm – 60 mm
- Guide wire max. 0.038″ (0,89 mm)
ANDRA2BALLON
The new Andra2Balloon is the new generation of non-compliant PTA-Catheters optimized for the
sequential dilation of large volume vessel and especially usefull as a delivery system for intervention with AndraStent.
- Both AndraBalloons are NON-COMPLIANT Balloons.
- Special desing with short shoulders and radiopaque atraumatic TIP
- Optimized folding for better rewrapping and easy repassage
- Coaxial shaft design for fast inflation and deflation
- Optimized PTA-balloon for stent dilatation
- 2 Pt/Ir X-ray markers on the inner shaft


ANDRASTENT®
The AndraStent L/XL/XXL is a balloon-expandable stent and laser-cuted of Cobalt Chromium MP35N. It is delivered un-mounted for percutaneous transluminal angioplasty (PTA). A PTA balloon catheter is used for implantation of the stent.
- High radial force Cobalt Chromium bare metal stent
- Developed for large vessels
- Large product range diameters from 6 up to 32mm lengths from 13 up to 57mm.
Vascular Indications:
• Peripheral arterial occlusion disease
• Strong Claudications
• Critical ischaemia extremities
• Dissections
• Stenosis
• Residual stenosis after balloon dilatations
• Elastic stenosis post-bypass vascular anastomoses
• Vascular occlusions
• Insufficient angioplasty result.
ANDRAVALVULOTOME
The AndraValvulotome allows the exact cut of the venous valves, indicated for in-situ and ex-situ valvolutomie. By self-centering and self -sizing technology the OTW Valvulotome minimizes the risk of injury in the treated area.
- 4F & 5F Nitinol OTW-System
- Low profile valvulotomy catheter
- 3 Nitinol blades
- Self-centering due to the basket geometry
- Automatic adjustment to the vein diameter
- Atraumatic tip


ANDRASNARE
The AndraSnare is a flexible snare for the interventional retrieval of foreign bodies from vessels. The AndraSnare comprises a flexible nitinol wire with a special gold-plated atraumatic 3D snare loop. Available in two version, Andra Snare and Andra Snare Micro.
- Atraumatic Nitinol loop with gold coating for better visualization in the X-rays
- Pre-formed tip for better navigation
- X-ray marker at the distal end of shaft
- Shaft visible in X-rays
- Bend protection for shaft reinforcement at the Luer
- Luer connection
- Insertion part for simple insertion of the loop into the catheter
- Large torquer for best handling
- Nitinol wire for 1:1 control of the loop
LOOPMASTER – SOCHMAN SNARE
The LoopMaster Sochman Snare has been specially developed for removing foreign bodies from vessels that do not have “open catching end”. The LoopMaster Snare consists of a flexible nitinol wire with a special pre-configured 3D atraumatic nitinol snare head and the safety wire for fixation of the foreign body.
- Atraumatic distal end at the catching wire
- Nitinol Loop
- Catching wire
- X-Ray marker on distal end
- Flexible Shaft
- Bend protection
- Luer connector
- Large torquers for simple control of the catching Snare and the catching wire